TM 11-5985-334-34
Figure 2-21. Lock-out assembly, exploded view, MK-2044/G.
Section V. CLEANING, INSPECTION, AND REPAIR
reduced to less than 29 psi and then
WARNINGS
only with effective chip guarding and
Adequate ventilation should be
provided while using TRICHLORO-
personnel protective equipment. Do
not use compressed air to dry parts
TRIFLUOROETHANE.
Prolonged
when TRICHLOROTRIFLUORO-
breathing of vapor should be avoided.
ETHANE has been used. Compressed
The solvent should not be used near
air is dangerous and can cause serious
heat or open flame, the products of
bodily harm if protective means or
decomposition are toxic and irritating.
methods are not observed to prevent
S i n c e TRICHLOROTRIFLUORO-
chip or particle (of whatever size) from
E T H A N E dissolves natural oils,
being blown into the eyes or unbroken
prolonged contact with the skin should
skin of the operator or other personnel.
be avoided. When necessary, use
gloves w h i c h the solvent cannot
2-26. General
penetrate. If the solvent is taken in-
This section explains how to clean, inspect, and
ternally, consult a physician im-
repair d i s a s s e m b l e d components of the
mediately.
Compressed air shall not be used for
cleaning purposes except where
materials used during these procedures.
2-26