TM 32-5895-342-14&P
Table 5-4. Organizational Preventive Maintenance Checks and Services - Continued
D - Daily
M - Monthly
S - Semiannually
B - Biennially
W - Weekly
Q - Quarterly
A - Annually
H - Hours
ITEM
INTERVAL
Item to be
Procedures
Equipment will be reported
NO
DWMQSA
B
H
inspected
Not Ready (Red) if:
12
TOWER
a. Check for corrosion. Clean and/or paint
Grounding is too damaged
GROUNDING
(para 5-3), as necessary.
to function.
b. Check for mechanical tightness of hardware.
No replacement for
Tighten loose connections as necessary
defective hardware.
13
CONVENIENCE
Check for evidence of corrosion or damage.
OUTLETS
Replace as necessary.
14
PUBLICATIONS
Check that all publications are complete,
Essential publication is missing
serviceable, and current (including all current
or unusable.
publication changes). Request serviceable
and current publications as necessary,
15
MODIFICATIONS
a. Determine whether new applicable MWO's
Urgent MWO has not
have been published.
been applied.
b. Accomplish all URGENT MWO's
Urgent MWO has not been
immediately, as appropriate.
accomplished.
c. Schedule all NORMAL MWO's, as appropriate.
5-11