TM 32-5895-342-14&P
Table 5-4. Organizational Preventive Maintenance Checks and Services
NOTE
The "Item No." column shall be used as a source of item numbers for the "TM Number" column on DA Form 2404, Equipment
Inspection and Maintenance Worksheet, in recording results of PMCS.
Legend
D - Daily
M - Monthly
S - Semiannually
B - Biennially
W - Weekly
Q - Quarterly
A - Annually
H - Hours
ITEM
INTERVAL
Item to be
Procedures
Equipment will be reported
NO
DWMQSA
B
H
inspected
Not Ready (Red) if:
1
HARDWARE
a. Check for corrosion. Remove corrosion
Hardware is corroded
necessary.
b. Check hardware for proper torque (tables
No replacement for
2-3 and 24).
defective hardware.
2
OBSTRUCTION
Check obstruction lights. Replace bulb(s)
Obstruction lights will
LIGHTS
function.
3
ROPES AND
Check ropes and cables for wear, fraying,
Rope or cable is too deteri-
CABLES
corrosion, or any other type of deteriora-
orated to function and re-
tion. Replace ropes or cables if deteriorated.
placement is not available.
4
ELEVATOR
a. Check hoist motor for binding or other
Hoist motor will not func-
HOIST
damage. Replace hoist if defective (para.
tion properly.
5-14).
b. Check hoist cable for corrosi6n or damage.
Hoist cable is damaged
and replacement is unavail-
5-14), as necessary.
able.
c. Check hoist mounting hardware for wear
Hardware is badly worn
or looseness. Replace and/or tighten, as
and replacement is unavail-
necessary.
able.
5-8