TM 32-5895-342-14&P
(5) Connect primary power source. Be sure
tags match with terminal connections.
(1) Remove fastener screws that secure
junction box cover. Remove junction box cover.
5-14 ELEVATOR HOIST.
screws (6) that secure circuit breaker clamp (5).
Remove circuit breaker clamp.
(1) Detach free end of hoist cable (12) from
and screws (10) that secure 20-ampere breaker (9) and
top tower step. Using hoist control reel in cable, thread
three 15-ampere circuit breakers (14). Pull circuit
it through sheave (10) on tower top brace.
breakers from holders.
(2) On power junction box, set HOIST circuit
breaker to OFF position. Disconnect hoist control from
hoist assembly.
9.
(3) Remove four bolts (4), bevel washers (5),
(1) Insert each circuit breaker into its
hex nuts (6) and locknuts (7). Remove hoist assembly
respective holder.
Secure with four screws (10),
(8) from hoist mount (1).
lockwashers (7), and nuts (8).
(4) Remove four hex nuts (2) and locknuts (3)
(2) Install circuit breaker clamp (5). Secure
from anchor bolts in hoist pier. Remove hoist mount (1).
(3) Attach junction box cover. Secure with
fastener screws.
(1) Install hoist mount onto four anchor bolts
in hoist pier. Secure with four hex nuts (2) and locknuts
d. Junction Box Replacement. Refer to figure 2-
(3).
14.
(2) Install hoist (8) to hoist mount (1). Secure
(1) Remove hex nut and tower step. Install
with four bolts (4), washers (5), hex nuts (6) and
junction box mount plate (5). Replace tower step and
locknuts (7).
hex nut.
(3) Connect hoist control to hoist assembly.
(2) Install junction box assembly (7) on
On power junction box set HOIST circuit breaker to ON
junction box mount plate (6). Secure with four bolts (3);
position.
lockwashers (4), and hex nuts (5).
(4) Using hoist control, reel out hoist cable
(3) Install convenience outlet (2) to junction
(12). Thread cable through sheave on tower top brace.
box mount plate (6). Secure with bolt (3), lockwasher
Secure free end to top tower step.
(4), and hex nut (5).
(4) Connect all power leads to junction box
and convenience outlet. Be sure tags match with
terminal connections.
5-16