TM 11-6625-1702-35
CHAPTER 4
GENERAL SUPPORT TESTING PROCEDURES
4-1. General
b. Comply with the instructions preceding the
a. Testing procedures are prepared for use by
b o d y of each chart before proceeding to the
chart. Perform each test in sequence. Do not
general support maintenance shops responsible
for general support maintenance of electronic
vary the sequence. For each step, perform all
e q u i p m e n t to determine the acceptability of
the actions required in the C o n t r o l s e t t i n g s
r e p a i r e d electronic equipment. These proce-
columns; then perform each specific test proce-
d u r e , and verify it against its performance
dures set forth specific requirements that
standard.
repaired electronic equipment must meet before
it is returned to the using organization. These
4-2. Test Equipment, Tools, and Materials
p r o c e d u r e s may also be used as a guide for
All test equipment, tools, materials, and other
testing equipment which has been repaired at
direct support if the proper tools and test
equipment required to perform the testing
e q u i p m e n t are available. A summary of the
procedures given in this section are listed in the
chart below and are authorized under TA 11-17
and TA 11-100 (11-17).
Technical Manual
Nomenclature
National/NATO stock No.
TM 11-6625-200-12
TM 11-6625-535-15
TM 11-6625-446-15
6625-00-177-1639
Dummy Load, Electrical
DA-75/U.
TM 11-5820-670-20
5831-00-937-4686
Radio Set AN/ARC-131.
6625-00-935-0332
Cable Assembly, Radio
Tool Kit, Electronic
Equipment TK-100/G.
Tool Kit, Operations
Central TK-101/GSQ.
Tool Kit, Electronic
Equipment TK-105/G.
1
Equivalent ME-262D/U
2
Or Equivalent AN/USM-281A
4-3. Test Facilities
4-4. Physical Tests and Inspection
Primary power requirements are for 27.5 0.5
a. Test Equipment and Materials. N o t e s t
volts dc with a maximum capacity of 2 amperes.
For the operation of certain test equipment, 120
equipment or materials are required.
b. Test Connections and Conditions. R e m o v e
12 volts, 60-Hertz (Hz), single-phase power is
the test panel from the test set case, and remove
also required. Temperature, humidity, and
the dust cover from the test panel.
atmospheric pressure are not critical.
Change 3 4-1