TM 11-6625-1702-35
(4) Ground plane.
(5) Test radome.
a. Test Equipment and Materials.
b . Test Connections and Conditions. C o n -
(1) Power supply, 28 volt dc.
(2)
Radio
Set
AN/ARC-131,
or
equiva-
Use the test leads supplied. Insert the antenna
lent.
c o u p l e r into the test radome and mount on
the ground plane.
c. Procedures.
Control
settings
Performance standard
Test
procedures
Equipment under test
Test
equipment
Step No
None.
Adjust power supply to
Turn on power supply
Set RF SELECT switch
1
obtain a 27.5 volt
to OUTPUT. Set ME-
dc indication on test
Allow time for warm-
TER FUNCTION
set meter.
switch to 28 VDC.
up.
Set MANUAL TUNE
switch to OFF.
If antenna coupler is
Apply RF power to
Set MANUAL TUNE
2
None
type 437S1, an-
the test panel and
switch alternately to
tenna coupler re-
observe cyclic action
INCREASE FRE-
mains inactive. If
of the antenna
QUENCY and DE-
antenna coupler is
coupler.
CREASE FRE-
type 437S1A,
QUENCY.
antenna coupler
operates.
Performance standard
Performance test
4-11. Test Data Summary
d. Coupler test (para d . Coupler stops cycling
when RF power is
The chart below lists the performance stand-
removed.
ards for each individual performance test. Use
this chart to compare the values obtained dur-
ing testing with the performance standards Of
MHz or 76 MHz,
the test set.
forward and re-
reflected RF power
Performance test
Performance standard
readings on AN/
a. Dc meter scale test a. Input voltage 27.5
ARM115 agree with
1.3 volts dc.
readings recorded
b. Millivolt source test b . Millivolt output:
on AN/URM120
+250 12 mv;
10%.
250 12 mv.
f. Coupler 437S-1 re-
f. Antenna element
c. TUNE INDICATOR c. Repetition rate for in-
mains inactive.
test.
function test
dicator full bril-
Coupler 437S-1A
liance : 15 5 ms.
operates.
C h a n g e 1 4-9