TM 11-5985-371-12&P
Operator Daily Preventive Maintenance Checks and Services
Equipment Not
Item
Item to be Inspected
Ready/Available
No.
Procedure
If:
WARNING
See WARNING on previous page.
1
Mast.
Mast not vertical.
Make sure the mast
is straight and vertical .
2
Guys and antenna
Make sure the 12 guys
wires loose or not
are secure and reasonably taut.
secure.
3
Stakes or mast
, mast base and
base not firmly
are firmly
imbedded.
imbedded in the qround.
4
Rf Cable and Groundinq Cable.
Cables frayed, broken
Make sure the rf cable/cables
and grounding cable
or improperly posi-
and connectors are not loose. cut. kinked.
tioned.
broken, crushed, frayed or improperly positioned.
5
Safety Area Rope.
Safety area not roped
Make sure the safety area rope
, takes
off, or warning
warning strips
,and caution plates
(for
transmitting) are properly erected.