CE-1008
TABLE 4-2. TROUBLE ANALYSIS CHART (CONT)
Step
No.
Procedure
Normal Indication
Corrective Step
23
Switch the beam width change
The beam broadener will ex-
a) Check the beam broadener.
switch, S7, to the BEAM IN-
tend. The BEAM WIDTH
b) Check for 28 volts at the
CREASE position.
meter will move from left to
beam width change switch, S7.
right.
c) If the beam broadener operates
but the BEAM WIDTH meter
does not operate, check the
potentiometer on the beam
broadener.
d) Check for 28 volts at this beam
broadener potentiometer.
e) Check the BEAM WIDTH
meter.
24
Set the beam width change
Reverse action of the beam
Same as step 23.
switch, S7, to the BEAM
increase.
DECREASE position.
25
Set the SAFE-RUN switch on
The SAFETY ON lights on
a) Check the light bulb.
each pedestal to the SAFE
the Control Indicator will
b) Check the switch.
position.
not drive.
4-11