TM 11-5985-370-12
CHAPTER 3
OPERATOR/CREW MAINTENANCE
SECTION I. TROUBLESHOOTING PROCEDURES
3-1. TROUBLESHOOTING GUIDELINES
The simple and rugged construction of ANTENNA GROUP OE-303/GRC reduces troubleshooting and
maintenance procedures.
The following table covers the troubleshooting steps you should take if there is a communications failure. If
your trouble cannot be corrected, notify C-E ORG MAINTENANCE.
The table does not cover troubleshooting the radio set. Before troubleshooting the antenna, make sure that
the radio is not the cause of the trouble by using the radio set troubleshooting guidance in the Radio Set
Technical Manual.
TABLE 3-1. TROUBLESHOOTING
TROUBLE
Test or Inspection
. Corrective Action
STEP 1
Double check the magnetic azimuth heading of the HALF-RHOMBIC ANTENNA.
Reorient the HALF--RHOMBIC ANTENNA if it is not properly oriented.
STEP 2
Carefully check all antenna components and connections starting at the radio set.
Tighten loose connections and replace defective cables and/or components.
C-E ORG MAINTENANCE.
STEP 3
Reconnect the TRANSFORMERS so that the TERMINATION TRANSFORMER
is at the antenna end pointing towards the distant station.
3-1