TM 11-5985-370-12
When you reach the INPUT TRANSFORMER, neatly and carefully:
l Connect the 6 inch ground wire on the end of the DISSIPATION CABLE to the
GROUND BINDING POST on the INPUT TRANSFORMER:
Push in the BINDING POST and attach the wire.
l Check to see that the shrunken TUBING SEAL on the end of the DISSIPATION
CABLE is good.
2-16. NORMAL OPERATION WITH A RADIO
The radio set is connected to the HALF-RHOMBIC ANTENNA using the 50'
RADIO CABLE.
NO ADJUSTMENT IS NECESSARY.
After a period of operation, make the following checks:
MAKE SURE THE RADIO SET IS TURNED OFF.
ARE THEY LEAKING, CRACKED OR TOO HOT TO TOUCH?
CONDITION OF THE DISSIPATION CABLE:
IS THE CABLE TOO HOT TO TOUCH?
Report any problems to C-E ORG MAINTENANCE.
2-34