CE-1008
TABLE 5-13. ANTENNA CONTROL POWER SUPPLY, LOCATION AND
FUNCTION OF TEST POINTS AND ADJUSTMENTS
Figure
Test Point or
Function
Ref.
Adjustment
1.
5-20
TP1, +28 VDC
Test point for checking the voltage level of the
Unregulated
+28 volts in unregulated DC.
2.
5-20
TP2, Chassis Ground
Test point for ground connection.
Test Point
14.
5-29
R6, Radome Pressure
Allows adjustment of the maximum deflection of
Gauge M1, Max. Adj.
the needle on pressure gauge M1.
Pot.
15.
5-20
R3, Radome Pressure
Allows adjustment of the minimum deflection of
Gauge M1, Min. Adj.
the needle on pressure gauge M1.
Pot.
23.
5-20
TP3, +24 VDC
Test point for checking the voltage level of the
Regulated
+24 volts regulated DC.
25.
5-20
R1, +24 VDC Regulated
Allows adjustment of the level of the regulated DC
Adjustment
voltage.
5-103