TABLE 5-11. ANTENNA POSITION CONTROL INDICATOR, LOCATION
AND FUNCTION OF TEST POINTS AND ADJUSTMENTS
Figure
Test Point or
Ref.
Adjustment
Function
TP2, Azimuth Error
Test point for checking the azimuth slave or manual error
Input
input to azimuth servo amplifier AR2.
TP1, Elevation Error
Test point for checking the elevation error input to
Input
elevation servo amplifier AR1.
Adjustment for setting the range around which the
Level Set Potentiometer
antenna will sector scan.
R8, Cable Wrap Meter
Allows adjustment of the maximum deflection of the
Max. Adj. Pot.
needle on CABLE WRAP meter M1.
R7, Cable Wrap Meter
Allows adjustment of the minimum deflection of the
Min. Adj. Pot.
needle on CABLE WRAP meter M1.
R5, Beam Width Meter
Allows adjustment of the minimum deflection of the
Min. Adj. Pot.
needle on the BEAM WIDTH meter M2.
R6, Beam Width Meter
Allows adjustment of the maximum deflection of the
Max. Adj. Pot.
needle on BEAM WIDTH meter M2.
Establishes the center position of the angle to be scanned
Potentiometer
during sector scan operation.
S8, Sector Scan Limit
Limits sector scan to 270 degrees.
Switch
5-93