TM 11-5821-284-34
Test equipment
Performance
Step
control settings
Figure ref.
Test procedure
standard
7
Same as step 6.
Measure de voltage at
More than +9. 0 Vdc.
8
Same as step 6, except
Measure de voltage at
More than +3. 0 Vdc.
set AN/ARM-115
A1A6B-7.
MANUAL TUNE to
INCREASE
9
Same as step 8.
Measure de voltage at
More than +3. 0 Vdc.
AlA6C-lil.
10
Same as step 6.
Measure dc voltage at
Less than +0. 3 Vdc.
AllA6A-3.
11
Same as step 8.
Measure de voltage at col- Less than +0. 3 Vdc.
and 5-9
lector of AQ15
Figure 5-5. Test connections, sequencing circuit test.
5-8